Lesson 8.2 of 8.3

Estimated time: about 2 minutes

Tests and protecting the distress frequencies

Test without disturbing anyone.

Distress and safety frequencies are protected: keep tests on them to a minimum, avoid harmful interference, and never transmit without authorisation (CEPT GOC C1 1.4). Tests and drills must never cause false alerts (MSC.514(105)).

The UK MCA routine shows what a typical flag State asks, and must be recorded: daily, test the DSC facilities without radiating, test the batteries and charge them if needed, and check the printers have paper; weekly, make a DSC test call to a coast station when in range (and test a non-battery reserve source); monthly, self-test each EPIRB without using the satellite system, test each SART, check battery security and condition and the aerials and insulators, and test each survival craft VHF on a channel other than 16 (MCA Master's Guide).

Your own flag State may word it differently: follow its rules and your company's procedures.

  • A DSC test call is a call, not a distress alert: use the test function, never the distress button.
  • Once a year at most, check the reserve battery capacity, not at sea (SOLAS IV/13.6.2).
A GMDSS radio log open at the console, with UTC times and entries.
Illustrative image

Check this lesson

Question 1/2

Which tests does the MCA ask for monthly?